- Dental Arches are originally well aligned
- Mandible is in posterior rest position
- Skeletal discrepancy is not severe
- Labial tipping of upper incisors is not evident
Ortho Lab Solution - Functional Appliances
**Twin Block dari Dr. William Clark**
Twin Block appliances are simple bite blocks that are designed for full-time wear. They achieve rapid functional correction of malocclusion by the transmission of favourable occlusal forces to occlusal inclined planes that cover the posterior teeth. The forces of occlusion are used as the functional mechanism to correct the malocclusion. (http://www.twinblocks.com/twin-blocks/)
Twin Block adalah alat ortodontik yang dikembangkan oleh Dr. William J. Clark yang bertujuan untuk memperpanjang rahang bawah dengan memposisikannya ke depan.
Jika rahang tumbuh selama perawatan, secara alami tumbuh lebih cepat; jika tidak, alat ini tidak berguna.
Waktu perawatan bervariasi, tetapi umumnya sekitar 9 bulan.
Twin Block juga dapat digunakan untuk mempebaiki overbite, yang bisa berarti perawatan mungkin sedikit lebih lama. Jika ini masalahnya, perawatan dapat bervariasi dari 6 hingga 11 bulan.
** Reverse Twin Block **
Reverse Twin Block untuk perawatan kelas 3.
** Twin Block dengan menggunakan sepasang screw (Acc. Dr. Marc Geserick)**
Twin Block biasa digunakan untuk koreksi Kelas 2. Aktivasi bukan dengan menambahkan acrylic melainkan dengan mengaktivkan screws.
**Frankel**
The Frankel appliances are removable designs invented by Professor Rolf Frankel. The Frankel philosophy uses the vestibules to enhance favorable growth in developing dentition and restrict undesireable muscle forces. Thus, the Frankel appliance is reported to provide an “ideal” environment for maximum arch development and proper skeletal jaw relationship. The three most commonly used designs are the Frankel II, Frankel III and Frankel IV.
How To Send A Case
All Functional Appliance designs require accurate working models. A construction bite should be provided to indicate the amount of mandibular advancement. Acrylic designs require a posterior opening of 2mm to 3mm to allow for proper appliance fabrication.
Frankel II
Frankel III
**Activator**
This was one of the first functional appliances that was developed to correct functional jaw in the early 1900s. Activator appliance became the universal appliance that was used widely throughout Europe in the earlier part of the 20th century.
Indication:
Activator appliance was initially indicated in patient's who are growing. Therefore, young adolescents with growth potential showed the best results of this appliance. In addition, a patient with retrognathic mandible, well aligned maxillary and mandibular dentition were also other indications of this appliance. Some of the malocclusions that can be treated with this appliance included Class II Division I, Class II Division II, Class III and Open Bites. (https://en.wikipedia.org/wiki/Activator_appliance)
**Bionator**
Bionator appliance is an Orthodontic functional appliance that was used to correct different malocclusions in orthodontics. The appliance was developed by Wilhelm Balters and it was designed to be a daytime appliance and less bulky compared to the Activator appliance. The appliance was primarily designed to be used in Class 2 Division 1 malocclusions. Bionator appliance was created due to the fact that 50 years of use of Activator appliance made it to too bulky for patient's to be compliant with their orthodontic treatment.
Indications:
Some of the disadvantages of this appliance is easier distortion when in the mouth. If the appliance is used in a patient with severe skeletal deformity, then the change of tongue function is secondary compared to the skeletal deformity. The indications for this appliance are reduced due to no allowance for vertical component, unlike other appliances such as Twin-Block or Activator.
(https://en.wikipedia.org/wiki/Bionator_appliance)
**Class II Bite Jumping Appliance Sander II**
Indications therapy of class II anomalies (mandibular retrusion) with growing children. Single tooth movements in both jaws, retrusion of upper anteriors, protrusion of lower anteriors or e.g. transversal expansions of both arches are possible at the same time. Active compliance of the patient is constantly required. Components/mode of operation The Bite JumpingSander II consists of two removable active plates for maxilla and mandible with two corresponding elements the Sander II Maxillary Expansion Screw can be with integrated memory spring as well as the Sander II Mandibular Memory Expansion Screw with holder and mounting plate for the inclined plane. The springs have a deflection of 0.8 mm each, and a spring force of 500 g. A maximum expansion of 9 mm can be achieved. The forward movement of the mandible is created by the interaction of protrusion bars and inclined plane. When the mouth is closed, the maxillary bars are sliding over the inclined plane incorporated in the mandibular plate. Through this force transmission the lower jaw is moved forward.
** Class III Appliance with Sander III
The S III aperture is a functional orthodontic appliance, because the force which is transferred to the upper jaw, can only be generated by the chew muscles. The condition for the application of the S III aperture is the anchorage possibility of the appliance. Through the assembly of the memory screw in the upper jaw, a fast transversal bodily expansion can be reached, particularly for young patients without the need for palatal expansion. The wanted backwards push can be adjusted step by step at both screws in the lower jaw.
Children can only effectively be treated, if they get the S III appliances early enough, that means before they are at the age of 9. Not suitable is the therapy for patients with oversized mandibular or with the family anamnesis prognosis for a strong lower jaw growth.
Ortho Lab Solution
Orthodontic Lab Kepercayaan Anda
Jl. Walikota Mustajab 59C
Surabaya 60272
Indonesia
Tel: +62 31 5346093
Untuk pemesanan dan Informasi:
Mobile/ WA: +62 812 5261 4640
Untuk Technical Support:
Mobile/ WA: +62 895 346 124 184
Email: ortholabsolution@gmail.com































Terima Kasih